Overview of the rotary laser indicators
Laser beam | Rotation of the laser beam | ||||||
---|---|---|---|---|---|---|---|
Green | Red | Green | Red | Red | |||
Switching on the measuring tool (1 s self-check) | ● | ● | ● | ||||
Levelling in or re-levelling | 2 ×/s | ○ | 2 ×/s | ||||
Measuring tool levelled in/ready for operation | ● | ● | ● | ||||
Self-levelling range exceeded | 2 ×/s | ○ | ● | ||||
Shock-warning function activated | ● | ||||||
Shock-warning actuated | 2 ×/s | ○ | 2 ×/s | ||||
Battery voltage for ≤ 2 h operation | 2 ×/s | ||||||
Batteries drained | ○ | ○ | ● |
●: Continuous operation
2 ×/s: Flashing frequency (e.g. twice per second)
○: Function stopped