Technical data
Wet/dry dust extractor | GAS 20 L SFC | |
---|---|---|
Article number | 3 601 J7B 1.. | |
Rated voltage | V | 220–240 |
Rated power input | W | 1200 |
Frequency | Hz | 50–60 |
Container volume (gross/net) | l | 19/15 |
Net volume (liquid) | l | 11.5 |
Dust bag volume | l | 7.5 |
Max. vacuumA) | ||
| hPa | 202 |
| hPa | 215 |
Max. volume flow rateA) | ||
| l/s m³/s | 31.5 0.0315 |
| l/s m³/s | 62 0.062 |
Max. suction power | W | 245 |
Area of pleated filter | m² | 0.28 |
Dust class | L | |
Weight according to EPTA-Procedure 01:2014 | kg | 6.4 |
Protection class | /I | |
Dust extractor protection rating | IPX4 | |
Mains plug Switzerland protection rating | IP55 |
- A)
Measured using a vacuum hose 3 m long and 35 mm in diameter
The specifications apply to a rated voltage [U] of 230 V. These specifications may vary at different voltages and in country-specific models.
Values can vary depending upon the product and are subject to application and environmental conditions. For further information www.bosch-professional.com/wac.
Automatic start/stopA) | |||
---|---|---|---|
Rated voltage | Maximum power | Minimum power | |
EU | 230 V | 2000 W | 100 W |
FR | 230 V | 2000 W | 100 W |
UK | 230 V | 1700 W | 100 W |
CH | 230 V | 1100 W | 100 W |
DK | 230 V | 1100 W | 100 W |
- A)
Permitted connected load of the connected power tool (country-specific)