Rectifying errors
Rotary laser display indicator | Laser receiver display indicator | Problem | Corrective measure | |
---|---|---|---|---|
– | Automatic shut-down (empty rechargeable/non-rechargeable battery) | Change the rechargeable or non-rechargeable battery as necessary. | ||
– | Automatic shut-down (operating temperature exceeded) | Adjust the measuring tool to the ambient temperature before switching it on. Then check the measuring accuracy and calibrate the measuring tool if required. | ||
−/PNK | Unsuccessful attempt to connect to the remote control (40) or the laser receiver (41) | Briefly press the on/off button (11) to close the error message. Start the connection process again see Establishing a connection to the remote control/laser receiver. | ||
– | Unsuccessful attempt to connect to the mobile device | Briefly press the on/off button (11) to close the error message. Start the connection process again see Remote control via Bosch Levelling Remote App. | ||
– | Measuring tool is at a slant of more than 8.5 % or is not in the correct horizontal or vertical position. | Reposition the measuring tool so that it is in either the horizontal or vertical position. The re-levelling will start automatically. | ||
– | Maximum levelling time is exceeded | Reposition the measuring tool so that it is in either the horizontal or vertical position. Briefly press the on/off button (11) to restart levelling. | ||
– | Change between the horizontal and vertical position without switching the measuring tool on/off | Briefly press the on/off button (11) to restart levelling. | ||
ERR | Unsuccessful calibration of the X-axis | Cancel the calibration with by pressing the button for line operation (5). | ||
ERR | Unsuccessful calibration of the Y-axis | |||
– | Unsuccessful calibration of the Z-axis | Cancel the calibration with by pressing the button for line operation (5). Check that the measuring tool is aligned correctly and restart calibration. | ||
ERR | Unsuccessful CenterFind mode in relation to the X-axis | Press any button to close the error message. | ||
ERR | Unsuccessful CenterFind mode in relation to the Y-axis | |||
GRL 650 CHVG: | ||||
ERR | Unsuccessful CenterLock mode in relation to the X-axis | Press any button to close the error message. | ||
ERR | Unsuccessful CenterLock mode in relation to the Y-axis |