Technical data

Digital laser measure

GLM 40

Article number

‎3 601 K72 9..‎

Measuring rangeA)

0.15–40 m

Measuring range (unfavourable conditions)B)

20 m

Measuring accuracyA)

±1.5 mm

Measuring accuracy (unfavourable conditions)B)

±3.0 mm

Smallest display unit

1 mm

General

Operating temperatureC)

–10 °C to +45 °C

Storage temperature

–20 °C to +70 °C

Relative air humidity max.

90 %

Max. altitude

2000 m

Pollution degree according to IEC 61010-1

2D)

Laser class

2

Laser type

635 nm, < 1 mW

Divergence of the laser beam

< 1.5 mrad (full angle)

Automatic switch-off after approx.

  • Laser

20 s

  • Measuring tool (without measurement)

5 min

Batteries

2 × 1.5 V LR03 (AAA)

Weight according to EPTA-Procedure 01:2014

0.09 kg

Protection ratingE)

IP 54 (dust and splash-proof)

Dimensions

105 × 41 × 24 mm

Unit of measurement setting

m, ft, in

Sound setting

A)

When measuring from the back edge of the measuring tool, this applies for high reflectivity of the target (e.g. a wall painted white), weak background lighting and a 20 °C operating temperature; a distance-dependent deviation of ±0.05 mm/m must additionally be factored in.

B)

When measuring from the back edge of the measuring tool, this applies for high reflectivity of the target (e.g. a wall painted white), strong background lighting, 20 °C operating temperature and high elevation. In addition, a deviation of ±0.15 mm/m must be taken into account, depending on the distance.

C)

In continuous measurement mode, the max. operating temperature is +40 °C.

D)

Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

E)

Except battery compartment

The serial number (9) on the type plate is used to clearly identify your measuring tool.