Technical data

Wet/dry dust extractor

GAS 55 M AFC

Article number

‎3 601 JC3 3..‎

Rated power input

W

1200

Frequency

Hz

50–60

Container volume (gross)

l

55

Net volume (liquid)

l

40

Dust bag volume

l

27

Max. vacuumA)

  • Dust extractor

hPa

230

  • Turbine

hPa

254

Max. volume flow rateA)

  • Dust extractor

l/s

m³/s

m³/h

36

0.036

129.6

  • Turbine

l/s

m³/s

m³/h

74

0.074

266.4

Max. suction power

W

1380

Area of pleated filter

0.615

Dust class

M

Weight according to EPTA-Procedure 01:2014

kg

16.2

Protection class

/I

Protection rating

IPX4

A)

Measured using a vacuum hose 3 m long and 35 mm in diameter

The specifications apply to a rated voltage [U] of 230 V. These specifications may vary at different voltages and in country-specific models.

Values can vary depending on the product, scope of application and environmental conditions. To find out more, visit www.bosch-professional.com/wac.

Automatic start/stop

Rated voltage

Maximum power

Minimum power

230 V

2200 W

100 W

Permitted connected load of the connected power tool.
These values can differ for other country-specific models. Please take note of the information on the socket of the dust extractor.