Rectifying faults

Problem

Corrective measures

Suction turbine will not switch on.

  • Check the mains cable, mains plug, fuse and socket.

The mode selector switch (1) is set to "automatic start/stop".

  • Set the mode selector switch (1) to the "extraction" symbol or switch on the power tool plugged into the plug socket (2).

The suction turbine will not switch on again after the container has been emptied.

  • Switch the dust extractor off and wait 5 seconds before switching it back on.

The suction power is decreasing.

  • Empty the container (7).
  • Remove any blockages from the vacuum nozzle, suction tube (26), vacuum hose (15) or main filter (20).
  • Change the plastic bag (19) or dust bag.
  • Make sure the filter holder (29) is engaged correctly.
  • Place the top part of the dust extractor (10) on correctly and close the catches (9).
  • Change the pre-filter (22), main filter (20) or wet filter (21).

Dust is escaping during extraction

  • Check that the main filter (20) has been fitted correctly.
  • Change the main filter (20).

Automatic switch-off (wet extraction) is not working.

Automatic switch-off will not work in the presence of non-conductive liquids or foaming.

  • Check the fill level regularly.

The semi-automatic filter cleaning function is not working.

  • Empty the container (7).