Rectifying faults

Problem

Corrective measure

Suction turbine will not switch on.

  • Check the mains cable, mains plug, fuse, socket and float (29).
  • Briefly press the on/off button (4) or switch on the power tool (3) that is connected to the socket.

The suction turbine switches off.

  • Empty the container (1).

The suction turbine will not switch on again after the container has been emptied.

  • Switch the dust extractor off and wait 5 seconds before switching it back on.
  • Clean the float (29).

The suction power is decreasing.

  • Remove any blockages from the vacuum nozzle, suction tube (21), vacuum hose (17) or pleated filter (28).
  • Change the disposal bag (20) or dust bag.
  • Place the top part of the dust extractor (6) on correctly and close the catches (7).
  • Change the pleated filter (28).

Dust is escaping during extraction

  • Check that the pleated filter (28) has been fitted correctly.
  • Change the pleated filter (28).

Automatic switch-off (wet extraction) is not working.

  • Clean the float (29).

Automatic switch-off will not work in the presence of non-conductive liquids or foaming.

  • Check the fill level regularly.