Rectifying Errors
Problem | Cause | Corrective measure |
---|---|---|
Suction turbine will not switch on. | Rechargeable (31) low on power | Charge or replace battery |
Restart protection triggered | First turn on/off switch to position 0, then to position 1 | |
On/off switch (14) in position, but no Auto-Start Remote GCT … is connected | Turn on/off switch to position 1 | |
The suction turbine switches off. | Container (12) full | Empty the container |
The suction turbine will not switch on again after the container has been emptied. | Reset required | Switch off the dust extractor, remove the rechargeable battery (31), wait 5 s, insert the rechargeable battery and switch on the dust extractor |
Dust extractor switches off too late with the Auto-Start function. | Run-on time has been set for too long | Shorten the run-on time via the Bosch Toolbox app (minimum run-on time: 6 s) |
The suction power is decreasing. | Plastic bag (36) is full | Replace the plastic bag |
Suction nozzle, suction tube (29) or vacuum hose (20) is blocked | Remove blockages | |
Main filter (32) is soiled or defective | Carry out manual filter cleaning, clean or replace the main filter | |
Main filter (32) has not engaged in the filter holder (35) | Make sure that the main filter has correctly engaged | |
Top part of the dust extractor (15) is not seated correctly | Place the top part of the dust extractor on correctly and close the catches (13) | |
Dust escapes during dry extraction | Main filter (32) has been fitted incorrectly | Check that the main filter has been fitted correctly |
Main filter (32) is defective | Change the main filter | |
Water escapes during wet extraction | Float (44) is blocked | Continually check the fill level and empty the container (12) in good time Wipe down the float cage with a damp cloth and clean the float by lightly shaking the dust extractor If the float and float cage become heavily contaminated, contact an authorised Bosch after-sales service centre. |
Temperature warning triggered (statusbar (2) lights up red) | Rechargeable battery (31) or motor overheated | Switch off the dust extractor, remove the rechargeable battery, and allow the rechargeable battery and the dust extractor to adjust to the ambient temperature |
Air flow alarm triggered (air flow alarm indicator (1) flashes yellow) | Follow the instructions in the corresponding section see Air Flow Alarm. | |
Manual filter cleaning cannot be triggered. | Contact an authorised Bosch after-sales service centre. | |
Electrostatic discharge | Dissipation of electrostatic charging has been interrupted | Ensure that the vacuum hose (20) is always in contact with the ground during operation. Check that there is no defect in the contact of the spring (51) with the bag holder (33). If necessary, repair the bag holder attachment see Repairing the Bag Holder Attachment (see figure R). |