Technical data
Digital detector | GMS 100-23 |
---|---|
Article number | 3 601 K81 800 |
Max. detection depthA) | |
| 100 mmB) |
| 80 mmC) |
| 50 mmD) |
Operating temperature | –10 °C to +50 °C |
Storage temperature | –20 °C to +70 °C |
Operating frequency range | 50 ± 2 kHz |
Max. magnetic field strength (at 10 m) | 42 dBµA/m |
Max. altitude | 2000 m |
Relative air humidity max. | |
| 90 % |
| 50 % |
Pollution degree according to IEC 61010-1 | 2E) |
Power supply | |
| 2 × 1.5 V LR6 (AA) |
| 2 × 1.2 V HR6 (AA) |
| 3.7 V |
Operating time, approx. | |
| 9 h |
| 9 h |
| 7 h |
Weight | |
| 0.28 kg |
| 0.26 kg |
Dimensions (length × width × height) | 186 × 86 × 33 mm |
Protection rating | IP54 |
Lithium-ion battery pack (accessory) | BA 3.7V 1.0Ah A |
Article number | 1 607 A35 0N8 1 607 A35 17H |
- A)
Depends on material and size of the objects, as well as material and condition of the substrate
- B)
For a copper pipe with a 15 mm diameter
- C)
For reinforcing steel with a 12 mm diameter
- D)
Lower detection depth with non-live wires
- E)
Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
The serial number (14) on the type plate is used to clearly identify your measuring tool.
- The accuracy and detection depth of the measuring result may be negatively affected if the condition of the substrate is unfavorable.