Adjusting the laser

Note: To test the laser function, the power tool must be connected to the power supply.

  • Draw a straight cutting line on the workpiece.
  • Slowly guide the tool arm downwards using the handle (9).
  • Position the workpiece so that the teeth of the saw blade line up with the cutting line.
  • Hold the workpiece in this position and slowly guide the tool arm back up.
  • Clamp the workpiece.
  • Switch on the laser beams using the laser/worklight on/off button (54).

The laser beams must be flush with the cutting line on the workpiece along its entire length, even if the tool arm is guided downwards.

  • Loosen the two screws (67) on the laser protection cap (10) using the hex key (44).

1. Adjusting the right-hand laser beam:

  • Turn the right-hand set screw (68) using the hex key (44) until the entire length of the right-hand laser beam is flush with the cutting line marked on the workpiece.
    This also moves the left-hand laser beam.

One rotation anticlockwise moves the laser beam from left to right; one rotation clockwise moves the laser beam from right to left.

2. Adjusting the left-hand laser beam:

  • Turn the left-hand set screw (68) using the hex key (44) until the left-hand laser beam is the same distance away from the cutting line marked on the workpiece as the right-hand laser beam.

One rotation anticlockwise moves the laser beam from left to right; one rotation clockwise moves the laser beam from right to left.