Technical Data

Digital inspection camera

GIC 120 C

Article number

 

‎3 601 B41 2..‎‎‎‎

Rated voltage

  • With rechargeable battery

V=

10.8/12

  • With non-rechargeable batteries

V=

6

Non-rechargeable batteries (alkaline­ manganese)

4 × 1.5 V LR6 (AA)

Relative air humidity

%

5–95A)

Length of camera cable

m

1.2

Smallest bend radius of camera cable

mm

25

Camera head diameter

mm

8.5

Display resolution

320 × 240

Approx. operating time

h

2B)/6C)

Weight according to
‌EPTA-Procedure 01:2014

kg

0.64

Dimensions (length × width × height)

mm

217 × 90 × 49

Environmental conditions

  • Recommended ambient temperature during charging

°C

0 to +35

  • Permitted ambient temperature during operationD)

°C

–10 to +50

  • Permitted ambient temperature during storage without a rechargeable battery

°C

–20 to +70

  • Permitted ambient temperature during storage with a rechargeable battery

°C

–20 to +50

Recommended rechargeable batteries

GBA 10,8V...
GBA 12V...

Recommended chargers

GAL 12...

A)

Free of condensation

B)

With non-rechargeable batteries

C)

With rechargeable battery at 100 % brightness of the light in the camera head

D)

Limited performance at temperatures <0 °C