Rectifying Errors
- If a fault (e.g. a filter damage) occurs, the vacuum cleaner must be switched off immediately. The fault must be repaired before resuming operation.
Problem | Remedy |
---|---|
Suction turbine will not switch on. | Check the mains cable, mains plug, fuse, socket and fill level sensors (42). |
The main switch (2) is set to "automatic start/stop". Set the main switch (2) to the "extraction" symbol or switch on the power tool plugged into the plug socket (4). | |
The suction turbine switches off. | During wet extraction, the LED indicators A and M will flash slowly and simultaneously. Empty the container (1). |
During dry extraction, the LED indicators A and M will flash quickly and simultaneously: The overload protection on the dust extractor socket is activated. Switch off the power tool. | |
The dust extractor shuts down. | The dust extractor is overloaded due to the maximum voltage of the dust extractor plug socket being exceeded: The motor protection device is triggered. Send the dust extractor to an authorised Bosch after-sales service centre. |
The suction turbine will not switch on again after the container has been emptied. | Switch the dust extractor off and wait 5 s before switching it back on. |
Clean the fill level sensors (42) and the space between the fill level sensors (42) using a brush. | |
The suction power is decreasing. | Remove any blockages from the vacuum nozzle, suction tube, vacuum hose (27) or flat-pleated filter (31). |
Change the plastic bag (29)/fleece filter bag (37). | |
Make sure the filter cover (40) is engaged correctly. | |
Place the top part of the vacuum cleaner (12) on correctly and close the catches (15). | |
Change the flat-pleated filter (31). | |
Dust is escaping during extraction | Check that the flat-pleated filter (31) has been fitted correctly. |
Change the flat-pleated filter (31). | |
Automatic switch-off (wet extraction) is not working. | Clean the fill level sensors (42) and the space between the fill level sensors (42) using a brush. |
Check the fill level regularly. | |
The automatic filter cleaning function is not working. | Switch to manual mode by pressing the manual filter cleaning button (7). If the problem persists, contact an authorised Bosch after-sales service centre. |
Manual filter cleaning cannot be triggered. | Over-temperature protection of the dust extractor is activated. Pressing the manual filter cleaning button (7) continuously ten times has triggered the over-temperature protection. The over-temperature protection will be automatically suspended after 20 s. Pressing the manual filter cleaning button (7) continuously 30 times has triggered the over-temperature protection. The over-temperature protection will be automatically suspended after 4 min. If the problem persists, contact an authorised Bosch after-sales service centre. |
The automatic filter cleaning function is not activated. | Contact an authorised Bosch after-sales service centre. |