Technical Data
Tile laser | GTL 3 |
---|---|
Article number | 3 601 K15 2.. |
Working area (with laser target plate)A) | 20 m |
Angle accuracyB)C)D) | ±0.2 mm/m |
Operating temperature | –10 °C to +50 °C |
Storage temperature | –20 °C to +70 °C |
Max. altitude | 2000 m |
Relative air humidity max. | 90 % |
Pollution degree according to IEC 61010-1 | 2E) |
Laser class | 2 |
Laser type | 630−650 nm, < 2 mW |
C₆ | 2 |
Divergence | 4 × 2 mrad (full angle) |
Operating mode | continuous wave (CW) |
Batteries | 4 × 1.5 V LR6 (AA) |
Operating timeB) | |
| 18 h |
| 12 h |
Weight according to EPTA-Procedure 01:2014 | 0.44 kg |
Dimensions (length × width × height) | 156 × 102 × 98 mm |
Protection rating | IP54 (dust and splash-proof) |
- A)
The working range may be reduced by unfavourable environmental conditions (e.g. direct sunlight).
- B)
At 20–25 °C
- C)
The angle accuracy between the 45° laser line and the 90° laser line is a maximum of ±0.4 mm/m.
- D)
The values stated presuppose normal to favourable environmental conditions (e.g. no vibration, no fog, no smoke, no direct sunlight). Extreme fluctuations in temperature can cause deviations in accuracy.
- E)
Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
The serial number (6) on the type plate is used to clearly identify your measuring tool.