Adjusting the Mitre Angle

Setting Standard Mitre Angles (see figure H)

For quick and precise setting of commonly used mitre angles, detents (14) are provided on the saw table:

Leftward

Rightward

45°; 31.6°; 22.5°; 15°

15°; 22.5°; 31.6°; 45°; 60°

  • Loosen the locking knob (11) if it is tightened.
  • Pull the lever (12) and rotate the saw table (37) left or right to the required detent.
  • Release the lever again. The lever must be felt to engage in the detent.
  • Retighten the locking knob (11).

Setting Any Mitre Angle (see figure I)

The mitre angle can be set between 52° (left side) and 60° (right side).