Technical data

Digital detector

GMS 100-23

Article number

‎3 601 K81 800‎‎‎‎

Max. detection depthA)

  • Non-ferrous metals (copper)

100 mmB)

  • Ferrous metals

80 mmC)

  • Live wires 100–230 V (with voltage applied)

50 mmD)

Operating temperature

–10 °C to +50 °C

Storage temperature

–20 °C to +70 °C

Operating frequency range

50 ± 2 kHz

Max. magnetic field strength (at 10 m)

42 dBµA/m

Max. altitude

2000 m

Relative air humidity max.

  • For detecting objects

90 %

  • For classifying live cables

50 %

Pollution degree according to IEC 61010-1

2E)

Power supply

  • Non-rechargeable batteries (alkaline manganese)

2 × 1.5 V LR6 (AA)

  • Rechargeable batteries (NiMH)

2 × 1.2 V HR6 (AA)

  • Lithium-ion battery pack (accessory)

3.7 V

Operating time, approx.

  • With non-rechargeable batteries (alkaline manganese)

9 h

  • With rechargeable batteries (NiMH)

9 h

  • With lithium-ion battery pack (accessory)

7 h

Weight

  • With non-rechargeable batteries (alkaline manganese)/rechargeable batteries (NiMH)

0.28 kg

  • With lithium-ion battery pack (accessory)

0.26 kg

Dimensions (length × width × height)

186 × 86 × 33 mm

Protection rating

IP54

Lithium-ion battery pack (accessory)

BA 3.7V 1.0Ah A

Article number

1 607 A35 0N8

‎1 607 A35 17H‎‎‎‎

A)

Depends on material and size of the objects, as well as material and condition of the substrate

B)

For a copper pipe with a 15 mm diameter

C)

For reinforcing steel with a 12 mm diameter

D)

Lower detection depth with non-live wires

E)

Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

The serial number (14) on the type plate is used to clearly identify your measuring tool.