Aligning the Protective Guard (see figure F)
Press and hold the adjusting lever (7) for the protective guard.
- Using the knob (6), rotate the protective guard (5) to the required position.
Adjust the protective guard (5) such that sparking in the direction of the operator is prevented.
Release the adjusting lever (7) for the protective guard. Push the knob (6) in both directions in order to check or ensure that the protective guard (5) is engaged.
- The protective guard (5) must only be able to be rotated in the direction of the accessory while the adjusting lever (7) is actuated. Otherwise, the power tool must not be used any more under any circumstances and must be sent to the after-sales service.