Technical Data
Cross line laser | GLL 3-50 |
---|---|
Article number | 3 601 K63 8.. |
Working rangeA) | |
| 10 m |
| 5−50 m |
| 5 m |
Levelling accuracyB)C) | |
| ±0.3 mm/m |
| ±0.6 mm/m |
Self-levelling range | ±4° |
Levelling time | < 4 s |
Operating temperature | –10 °C to +40 °C |
Storage temperature | –20 °C to +70 °C |
Max. altitude | 2000 m |
Relative air humidity max. | 90 % |
Pollution degree according to IEC 61010-1 | 2D) |
Laser class | 2 |
Laser type | <1 mW, 630−650 nm |
C₆ | 1 |
Divergence of laser line | 0.5 mrad (full angle) |
Shortest pulse duration | 1/1600 s |
Pulse frequency (operating with receiver mode) | 800 Hz |
Recommended laser receiver | LR 2 |
Tripod mount | 1/4", 5/8" |
Batteries | 4 × 1.5 V LR6 (AA) |
Min. operating timeB) | 6 h |
Weight according to EPTA‑Procedure 01:2014 | 0.94 kg |
Dimensions (length × width × height) | |
| 146 × 83 × 117 mm |
| Dia.: 201 × 197 mm |
Protection rating | IP54 |
- A)
The working range may be reduced by unfavourable environmental conditions (e.g. direct sunlight).
- B)
At 20–25 °C
- C)
The values stated presuppose normal to favourable environmental conditions (e.g. no vibration, no fog, no smoke, no direct sunlight). Extreme fluctuations in temperature can cause deviations in accuracy.
- D)
Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
The serial number (11) on the type plate is used to clearly identify your measuring tool.