Technical Data

Thermal imaging camera

GTC 400 C

Article number

3 601 K83 1..

Resolution of infrared sensor

160 × 120 px

Thermal sensitivity

< 50 mK

Spectral range

8–14 μm

Field of view (FOV)

53 × 43°

Focus distance

≥ 0.3 m

Focus

Fixed

Thermal image refresh rate

9 Hz

Temperature resolution

0.1 °C

Surface temperature measuring range

–10 to +400 °C

Surface temperature measuring accuracy A)B)
–10 to ≤ +10 °C
> 10 to ≤ 100 °C
> +100 °C


±3 °C
±3 °C
±3 %

Display type

TFT

Display size

3.5"

Display resolution

320 × 240 px

Image format

.jpg

Images saved per saving process

1 x thermal image (screenshot)
1 x real visual image incl. temperature values (metadata)

Number of images in internal image memory

500

Integrated visual camera resolution

640 × 480 px

Batteries (alkali-manganese)
Rechargeable battery (Li-ion)

4 × 1.5 V LR6 (AA) (with battery adapter)
10.8 V/12 V

Operating time

  • Non-rechargeable batteries (alkaline manganese)

2.0 h

  • Rechargeable battery pack (Li-ion) C)D)

9.0 h

USB port

2.0

System time power supply

  • Coin cell

CR2450 (3 V lithium battery)

  • Battery life approx.

60 months

Wireless connectivity

Wi-Fi

Max. Wi-Fi transmission power

45 mW

Wi-Fi operating frequency range

2.402–2.480 GHz

Specific absorption rate (torso, average value per 10 g tissue)

< 0.22 W/kg

Weight according to EPTA-Procedure 01:2014

  • With rechargeable battery

0.54–0.74 kgC)

  • With non-rechargeable batteries

0.49 kg

Dimensions (length × width × height)

63 × 95 × 235 mm

Protection rating (excluding battery compartment)

IP53

Permitted environmental conditions

  • Recommended ambient temperature during charging

0 to +35 °C

  • Operating temperature

–10 to +45 °C

  • During storage with a rechargeable battery

–20 to +50 °C

  • During storage without a rechargeable battery

–20 to +70 °C

Max. altitude

2000 m

Pollution degree according to IEC 61010-1

2E)

Relative humidity max.F)

90 %

Recommended rechargeable batteries

GBA 10.8 V
GBA 12 V

Recommended chargers

GAL 12…
GAX 18…

A)

At an ambient temperature of 20 to 23 °C and an emissivity of > 0.999, measuring distance: 0.3 m, operating time: > 5 min, aperture of 60 mm

B)

Plus use-dependent deviation (e.g. reflection, distance, ambient temperature)

C)

Depends on battery in use

D)

At an ambient temperature of 20–30 °C

E)

Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

F)

In accordance with standard VDI 5585

Technical data determined using the battery that comes with the product.