Overview of status indicators

Measuring tool

Function

Green

Red

Horizontal position: X- or Y-axis levelling process
Vertical position: X-axis levelling process

Sleep mode activated

Horizontal position: Both axes are levelled.
Vertical position: X-axis is levelled.

Automatic shut-down due to error message (e.g. empty rechargeable/non-rechargeable battery, operating temperature exceeded)

CenterFind mode or CenterLock mode started (see operating instructions for the laser receiver)

Position of the measuring tool changed without switching on/off

Self-levelling not possible, end of the self-levelling range

Shock-warning function actuated

Calibration of the measuring tool is started.

Horizontal position: At least one axis is tilted or is in manual operating mode.
Vertical position: X-axis is tilted or in manual operating mode.

● lighting up continuously

◌ flashing

Remote control

Remote control

Function

Green

Red

Green

Red

X-axis levelling process (horizontal and vertical positions)

Y-axis levelling process (horizontal position)

Remote control is being connected via Bluetooth®.
(Both of the status indicators flash alternately.)

X-axis is levelled in (horizontal and vertical positions).

Y-axis is levelled in (horizontal position).

● (3 s)

● (3 s)

Remote control successfully connected via Bluetooth®

X-axis is tilted or in manual operating mode (horizontal and vertical positions).

Y-axis is tilted or in manual operating mode (horizontal position).

● (3 s)

● (3 s)

Unsuccessful connection to the measuring tool via Bluetooth®

● lighting up continuously

◌ flashing