Technical Data
Thermal imaging camera | GTC 400 C |
---|---|
Article number | 3 601 K83 1.. |
Resolution of infrared sensor | 160 × 120 px |
Thermal sensitivity | < 50 mK |
Spectral range | 8–14 μm |
Field of view (FOV) | 53 × 43° |
Focus distance | ≥ 0.3 m |
Focus | Fixed |
Thermal image refresh rate | 9 Hz |
Temperature resolution | 0.1 °C |
Surface temperature measuring range | –10 to +400 °C |
Surface temperature measuring accuracy A)B) |
|
Display type | TFT |
Display size | 3.5" |
Display resolution | 320 × 240 px |
Image format | .jpg |
Images saved per saving process | 1 x thermal image (screenshot) |
Number of images in internal image memory | 500 |
Integrated visual camera resolution | 640 × 480 px |
Batteries (alkali-manganese) | 4 × 1.5 V LR6 (AA) (with battery adapter) |
Operating time | |
| 2.0 h |
| 9.0 h |
USB port | 2.0 |
System time power supply | |
| CR2450 (3 V lithium battery) |
| 60 months |
Wireless connectivity | Wi-Fi |
Max. Wi-Fi transmission power | 45 mW |
Wi-Fi operating frequency range | 2.402–2.480 GHz |
Specific absorption rate (torso, average value per 10 g tissue) | < 0.22 W/kg |
Weight according to EPTA-Procedure 01:2014 | |
| 0.54–0.74 kgC) |
| 0.49 kg |
Dimensions (length × width × height) | 63 × 95 × 235 mm |
Protection rating (excluding battery compartment) | IP53 |
Permitted environmental conditions | |
| 0 to +35 °C |
| –10 to +45 °C |
| –20 to +50 °C |
| –20 to +70 °C |
Max. altitude | 2000 m |
Pollution degree according to IEC 61010-1 | 2E) |
Relative humidity max.F) | 90 % |
Recommended rechargeable batteries | GBA 10.8 V |
Recommended chargers | GAL 12… |
- A)
At an ambient temperature of 20 to 23 °C and an emissivity of > 0.999, measuring distance: 0.3 m, operating time: > 5 min, aperture of 60 mm
- B)
Plus use-dependent deviation (e.g. reflection, distance, ambient temperature)
- C)
Depends on battery in use
- D)
At an ambient temperature of 20–30 °C
- E)
Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
- F)
In accordance with standard VDI 5585
Technical data determined using the battery that comes with the product.