Rectifying Faults
Problem | Cause | Corrective measure |
---|---|---|
The power tool is not ready for operation. | The battery is discharged or defective. |
|
The battery is not properly inserted. |
| |
The battery temperature is too high or too low. |
| |
The battery contacts, motor or solenoid are dirty or defective. |
| |
The magazine (14) is empty. |
| |
The discharge lock-off (2) is bent. |
| |
The electronic system is defective. |
| |
The user interface (10) is defective. |
| |
The power tool is ready for operation, but no nails are discharged. | The following components may be faulty:
|
|
Foreign objects have accumulated in the shot mechanism. |
| |
Foreign objects have accumulated in the outlet (18) or in the magazine (14). |
| |
A nail is jammed in the shot duct. |
| |
The magazine slider (15) is defective. |
| |
The spring of the magazine slider is too weak or defective. |
| |
The fasteners being used are not approved. |
| |
The magazine (14) is empty. |
| |
The fasteners have been pressed in the wrong order. |
| |
The nails are driven in too deep. | The depth stop is set too deep. |
|
The buffer is worn. |
| |
The nails are not driven in deep enough. | The battery is discharged or defective. |
|
The fasteners are too long. |
| |
The depth stop is set too high. |
| |
The power tool skips nails or has a cycle feed that is too large. | The fasteners being used are not approved. |
|
The spring of the magazine slider is too weak or defective. |
| |
Nails are frequently jamming in the shot duct. | The fasteners being used are not approved. |
|
| ||
The nails are old, the adhesive between the nails has lost its retention force. |
| |
The driven nails are bent. | The driver blade is damaged. |
|
The nailer is being used on a material that is not permitted (e.g. concrete, stone). |
|