Technical data

Angle Grinder

GWS 20-230 P

GWS 20-230 J

Article number

‎3 601 HC1 1..‎

‎3 601 HC1 3..‎

Rated power input

W

2000

2000

Rated speed

min–1

6500

6500

Max. grinding disc diameter

mm

230

230

Grinding spindle thread

M 14

M 14

Max. thread length of grinding spindle

mm

25

25

Restart protection

Starting current limitation

Weight according to ‌EPTA-Procedure 01/2014

  • with low-vibration auxiliary handle

kg

5.5

5.5

  • with standard auxiliary handle

kg

5.4

5.4

Protection class

/ II

/ II

The specifications apply to a rated voltage [U] of 230 V. These specifications may vary at different voltages and in country-specific models.

Notes on mains connection requirements for GWS 20-230 P:

The appliance meets IEC 61000-3-11 requirements and is subject to conditional connection. The appliance can lead to occasional voltage fluctuations under unfavorable power conditions. The impedance of this appliance is set as Zactual0.18 Ω. The user must make sure, that the connection point, with the impedance Zmax, on which the appliance shall be plugged in meets the impedance requirement: Zactual ≥ Zmax. If Zmax is unknown, determine Zmax in consultation with the network supplier or supply authority.

Angle Grinder

GWS 22-230 P

GWS 22-180 J

GWS 22-230 J

Article number

‎3 601 HC1 1..‎

‎3 601 HC0 3..‎

‎3 601 HC1 3..‎

Rated power input

W

2200

2200

2200

Rated speed

min–1

6500

8500

6500

Max. grinding disc diameter

mm

230

180

230

Grinding spindle thread

M 14

M 14

M 14

Max. thread length of grinding spindle

mm

25

25

25

Restart protection

Starting current limitation

Weight according to ‌EPTA-Procedure 01/2014

  • with low-vibration auxiliary handle

kg

5.5

5.3

5.5

  • with standard auxiliary handle

kg

5.4

5.2

5.4

Protection class

/ II

/ II

/ II

The specifications apply to a rated voltage [U] of 230 V. These specifications may vary at different voltages and in country-specific models.

Notes on mains connection requirements for GWS 22-230 P:

The appliance meets IEC 61000-3-11 requirements and is subject to conditional connection. The appliance can lead to occasional voltage fluctuations under unfavorable power conditions. The impedance of this appliance is set as Zactual0.18 Ω. The user must make sure, that the connection point, with the impedance Zmax, on which the appliance shall be plugged in meets the impedance requirement: Zactual ≥ Zmax. If Zmax is unknown, determine Zmax in consultation with the network supplier or supply authority.